The Agilent 8591E is an easy-to-use RF spectrum analyzer that offers a wide range of performance, features, and optional capability to meet your measurement needs. Downloadable measurement personalities combine with optional plug-in performance to provide tailored solutions for your application.

 

  • Perform complex tests simply and quickly with measurement personalities that support applications like cable TV/broadcast, component test, electromagnetic compatibility, lightwave, and wireless communications
  • Four slot cardcage
  • Split screen display
  • One-button measurement routines
  • Advanced measurement functions
  • Dual interfaces
  • Built-in tracking generator
  • E4444A BenchLink software - (Purchasable for $426 from Agilent)
  • Frequency Specifications:
    Frequency Range: 9 kHz to 1.8 GHz
    Frequency Reference:
      Aging: ±2 x 10-6/year
      Temperature Stability: ±5 x 10-6
      Initial Achievable Accuracy: ±0.5 x 10-6
    Frequency Readout Accuracy (start, stop, center, marker): ±(freq. readout x freq. ref error + span accuracy + 1% of span + 20% of RBW + 100 Hz x N)
    Marker Count Accuracy:
      Span < or = to 10 MHz x N: ±(marker freq. x freq. ref error + counter resolution + 100 Hz x N)
      Span > 10 MHz x N: ±(marker freq. x freq. ref error + counter resolution + 1 kHz x N)
      Counter Resolution:
        Span < or = to 10 MHz x N: Selectable from 10 Hz to 100 kHz
        Span > 10 MHz x N: Selectable from 100 Hz to 100 kHz
    Frequency Span:
      Range: 0 Hz (zero span) and
      HP 8591E: 10 kHz to 1.8 GHz
      Resolution: Four digits or 20 Hz x N, whichever is greater
      Accuracy:
        Span < or = to 10 MHz x N: ±2% of span
        Span > 10 MHz x N: ±3% of span
    Sweep Time:
      Range:
        Span = 0 Hz or > 1 kHz: 20 ms to 100 s
      Accuracy:
        20 ms to 100 s: ±3%
      Sweep Trigger: Free run, single, line, video, external
    Resolution Bandwidth: 1 kHz to 3 MHz (3 dB) in 1, 3, 10 sequence; 9 kHz and 120 kHz (6 dB) EMI bandwidths
      Accuracy: ±20%
      Selectivity (characteristics):
        -60 dB/-3 dB: 3 kHz to 10 kHz, 15:1. 100 kHz to 3 MHz, 15:1
        -40 dB/-3 dB: 30 Hz to 300 Hz, 10:1
    Vision Bandwidth Range: 30 Hz to 1 MHz in 1, 3 sequence
    Stability:
      Noise Sidebands (1 kHz RBW, 30 Hz VBW, Sample Detector):
        > 10 kHz offset from CW Signal: < or = to -90 dBc/Hz + 20 log N
        > 20 kHz offset from CW Signal: < or = to -100 dBc/Hz + 20 log N
        > 30 kHz offset from CW Signal: < or = to -105 dBc/Hz + 20 log N
      Residual FM:
        1 kHz RBW, 1 kHz VBW: < or = to 250 Hz pk-pk in 100 ms
        30 Hz RBW, 30 Hz VBW: < or = to 30 Hz pk-pk in 300 ms
    System Related Sidebands (> 30 kHz offset from CW signal): < or = to -65 dBc + 20 log N

    Amplitude Specifications:
    Amplitude Range: Displayed average noise level to +30 dBm
    Maximum Safe Input Level (input attenuator > or = to 10 dB):
      Average Continuous Power: +30 dBm (1 W)
      Peak Pulse Power: ±30 dBm (1 W)
      DC: 25 VDC
    Gain Compression (> 10 MHz): < or = to 0.5 dB (total power at input mixer = -10 dBm)
    Displayed Average Noise Level (input terminated, 0 dB atten., 30 Hz VBW or 1 Hz VBW with option 130, sample detector):

    30 Hz RBW:
    1 kHz RBW:
    400 Hz to 1 MHz:
    < or = to -130 dBM
    < or = to -115 dBM
    1 MHz to 1.5 GHz:
    < or = to -130 dBM
    < or = to -115 dBM
    1.5 GHz to 1.8 GHz:
    < or = to -128 dBM
    < or = to -113 dBM


    Spurious Responses:
      Second Harmonic Distortion (5 MHz to 1.8 GHz): < -70 dBc for - 45 dBm tone at input mixer
      Third Order Intermodulation (5 MHz to 1.8 GHz): < -70 dBc for two -30 dBm tones at input and > 50 kHz separation
      Other Input-Related Spurious (30 kHz offset, -20 dBm tone at input mixer): < -65 dBc
    Display Range:
      Log Scale: 0 to -70 dB from ref level is calibrated; 0.1, 0.2, 0.5 dB/div and 1 to 20 dB/div in 1 dB steps; 8 div displayed
      Linear Scale: 8 divisions
      Scale Units: dBm, dBmV, dBµV, V, W
    Marker Readout Resolution:
      Log Scale: 0.05 dB
      Linear Scale: 0.05% of ref level
    Reference Level:
      Range: Same as amplitude range
      Resolution: ±0.01 dB for log scale; ±0.12% of ref level for linear scale
      Accuracy: ±0.3 dB at -20 dBm; 0 to -59.9 dBm: ±(0.3 dB + 0.01 x dB from -20 dBm)
    Frequency Response (10 dB Input Attenuation):   Absolute (referenced to 300 MHz CAL OUT): ±1.5 dB
      Relative Flatness (referenced to midpoint between highest and lowest frequency response deviations): ±1.0 dB
    Resolution Bandwidth Switching Uncertainty (ref to 3 kHz RBW, at ref level):
      3 kHz to 3 MHz RBW: ±0.4 dB
      1 kHz RBW: ±0.5 dB
      30 Hz to 300 Hz RBW: ±0.6 dB
    Log to Linear Switching: ±0.25 dB at ref level
    Display Scale Fidelity:
      Log Incremental Accuracy (0 to -60 dB from ref level): ±0.4 dB/4 dB
      Log Maximum Cumulative (0 to -70 dB from ref level):     3 kHz to 3 MHz RBW: ±:(0.3 + 0.01 x dB from ref level)
        30 Hz to 1 kHz RBW: ±(0.4 + 0.01 x dB from ref level)
      Linear Accuracy: ±3% of ref level

    General Specifications:
    MIL-T-28800: Has been type-tested to the environmental specifications of MIL-T-28800 Class 5
    Temperature:
      Operating: 0° to +55°C
      Storage: -40° to +75°C
    EMI Compatibility: Conducted and radiated interference CISPR Pub. 11 and Messemfaenger Postverfuegung 526/526/79
    Audible Noise: < 37.5 dBA pressure and < 5.0 Beis power (ISODP7779)
    Power Requirements:
      ON (Line 1): 90 to 132 V rms, 47 to 440 Hz, 195 to 250 V rms, 47 to 66 Hz. Power consumption < 500 VA; < 180 W
      Standby (Line 0): Power consumption < 7 W
    User Program Memory (Nominal): 238 KB nonvolatile RAM
    Data Storage (Nominal):
      Internal: 24 traces or 32 states
      External: 50 traces, 8 states
      Memory Cards: HP 85700A (32 KB), 24 traces or 32 states; HP 85702A (128 KB), 99 traces or 128 states
      Video Cassette Recorder (VCR): Continuous video recording of display supported through composite video output
    Size (Nominal, without handle, feet, or cover): 325 mm W x 163 mm H x 427 mm D
    Weight: 14.5 kg

    Option 010 Built-in Tracking Generator Specifications:
    Frequency Range: 100 kHz to 1.8 GHz
    Output Level:
      Range: 0 to -70 dBm
      Resolution: 0.1 dB
      Absolute Accuracy: ±0.1 dB
    Vernier:
      Range: 10 dB
      Accuracy: ±0.75 dB
    Output Flatness: ±1.75 dB
    Spurious Output:
      Harmonic Spurs: 0 dBm +42.8 dBmV output, < -25 dBc
      Nonharmonic Spurs: < -30 dBc
    Dynamic Range (Characteristic; max. output level - TG feedthrough): 106 dB
    Power Sweep:
      Range: -75 dBm to 0 dBm
      Resolution: 0.1 dB